Добро пожаловать на Must Power.

PH2000 MPPT DTL Series Single Phase On Grid Solar Inverter (3.6-5KW) PH2000 MPPT DTL Series Single Phase On Grid Solar Inverter (3.6-5KW) PH2000 MPPT DTL Series Single Phase On Grid Solar Inverter (3.6-5KW)

Single Phase On Grid Solar Inverter

PH2000 MPPT DTL Series (3.6-5KW)

The unit is bidirectional which apply to PV system with battery to store energy. Energy produced by the PV system is used to optimize self-consumption; excess energy is used to charge the batteries, and then fed into the public grid when the PV energy is adequate, When PV energy output is in sufficient to support connected loads, the system automatically get energy from the batteries if battery capacity is abundant. If the battery capacity is insufficient to meet own consumption requirements, electricity will be drawn from the public grid.

Где купить?

Downloads: PH2000 MPPT DTL Series (3.6-5KW).pdf

Обзор

ph2000a-1

LCD / LED информационный дисплей

1. The inverter power flow direction indicator
2. The inverter operation status indicator


Figure Back Panel Information

3. PV input terminals
4. Battery input terminals and cover
5. PV input switch
6. WIFI com module and USB port
7. BAT._NTC and RS485 communication (BMS com, load monitor com)
8. AC Output terminals and cover

ph2000a-2


ph2000aa

Схемы подключения солнечных батарей

  • Zero export to grid;
  • Reactive Power Control (RPC);
  • U-disk for software updating;
  • Light weight in small size;
  • Without LCD,no risk of dust or water;
  • Seperate APP setting/monitoring;
  • MUST Pad local monitoring;

Specifications PH20-3600DTL PH20-4200DTL PH20-4600DTL PH20-5000DTL
Input Data (DC)    
Max. DC power 4000W 4600W 5000W 5400W
Max. DC voltage 600V
Start voltage 100V
DC nominal voltage 360V
PV voltage range  100V-600V
MPP voltage range 120V-550V
Max. input current per string of tracker A/tracker B 11A/11A
Number of independent MPP inputs 2
Output Data (AC)    
Nominal AC output power 3600W 4200W 4600W 5000W
Max. AC apparent power 3600VA 4200VA 4600VA 5000VA
Max. output current 16.4A 19.1A 21.0A 22.8A
AC nominal voltage; range 220V/230V/240V; 180Vac-280Vac
AC grid frequency; range 50,60H;±5 Hz
Power factor at rate power 1
Power factor 0.9leading…0.9lagging
THDi <3%
AC connection Single phase
Efficiency  
Max. efficiency  97% 97.10% 97.10% 97.10%
Euro – eta 96.50% 96.50% 96.50% 96.50%
MPPT efficiency 99.50% 99.50% 99.50% 99.50%
Protection devices  
DC reverse polarity protection Yes
DC switch ratiing for each MPPT  Yes
Output over current protection Yes
Output overvoltage Protection-varistor Yes
Ground fault monitoring Yes
Grid monitoring Yes
Integrated all – pole sensitive leakage current monitoring unit Yes
General Data  
Dimensions (W / H / D) 380*300*150mm
Weight 11kg 12kg 13kg 13kg
Operating temperature range -25…+600C      (-13…+ 1400F)    with derating above 450C(1130F)
Noise emission (typical) ≤ 25 dB(A)
Altitude Up to 2000m (6560ft) without power derating
Relative humidity 95%
Consumption: operating (standby) / night <5W / < 0.5 W
Topology Transformerless
Cooling concept Natural
Environmental protection rating IP65
Features  
DC connection H4/MC4
AC connection Screw terminal
Display LED
Interfaces:  Wi-Fi/USB/GPRS/RS485 Yes/Yes/Opt/Opt
Warranty: 5 years / 10 years / 15 years Yes/Opt/Opt
Certificates and approvals CE,IEC 62109, VDE 0126-1-1, VDE-AR-N4105,RD1663,G59,G83, AS4777, AS/NZS 3100, CGC
*required
*required
*required
*required